7.1.2 Customization
When the set-up guidance functions are used on the multi-path lathe system,
note the followings.
7.1.2.1 P-Code Variables for Set-Up Guidance Function
The following parameters for the set-up guidance functions are common to all
path.
12381 Measurement condition variable start number
12382 Calibration variable start number
12383 Measurement execution variable start number
12384 Measurement result storage variable start number
12385 Number of variables for storing measurement results
12387 Number for a macro program for selecting a tool
12388 Number for a macro program for making measurements
If the P-CODE macro variables numbered #20000 for operating manual
measurement, not only the compile parameter of the first path user macro
module but the compile parameter of the second path and the third path are
necessary to set to use #20000.
The 2000 number of P-CODE macro variables numbered #10000 can be used
with the FANUC standard macro system for MANUAL GUIDE i. So, it is
possible to use these macro variables for the set-up guidance functions without
adding the user macro module.
Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-2
Page
FANUC LTD.
5/14