B-63874EN-1/02 2.MEASUREMENT CYCLE
- 85 -
The symbols used above have the following meanings:
A: Touch sensor position. If "SETTIN" is selected in "SPECIFY OF
MEAS. PT.", A represents the "sensor position for measurement
in the -Z direction" of the touch sensor position in the specified
measurement condition. If "INPUT" is selected in "SPECIFY OF
MEAS. PT.", A represents the coordinates specified by
"MEASURE POINT X", "MEASURE POINT Y", and
"MEASURE POINT Z".
Ax: X coordinate of the touch sensor position above
Ay: Y coordinate of the touch sensor position above
Az: Z coordinate of the touch sensor position above
fa: Value of "FEED-RATE FOR APPROACHING START POINT"
in the measurement condition of the group number specified in
"MEASUREMENT COND."
f: Value of “FEED-RATE FOR 1ST MEASUREMENT" in the
measurement condition of the group number specified in
"MEASUREMENT COND."
β: Value of "ESCAPING DISTANCE FOR 1ST
MEASUREMENT" in the measurement condition of the group
number specified in "MEASUREMENT COND."
γ: Value of "OVERLAP DISTANCE FOR MEASUREMENT" in
the measurement condition of the group number specified in
"MEASUREMENT COND."
ε: Value of "ESCAPING DISTANCE FOR 2ND
MEASUREMENT" in the measurement condition of the group
number specified in "MEASUREMENT COND."