B-63874EN-1/02 2.MEASUREMENT CYCLE
- 141 -
- WORK COORD. VALUE Y
Specify the Y coordinate of the measurement point in a specified
workpiece coordinate system.
Enter a numeric value.
- OK RANGE (±)
Specify an allowable range of errors obtained from measurement.
If the difference between the center coordinate obtained from
measurement and the correct value (input value "CENTER POINT X"
or "CENTER POINT Y") is within this allowable range, the absence
of errors is assumed, and no setting is performed as a workpiece
origin offset value.
Enter a numeric value.
- FEED BACK RANGE (±)
If an error obtained from measurement is not within the OK range but
is within this feedback range, the measured value is set in the setting
destination.
If an error obtained from measurement exceeds the feedback range, an
alarm is issued.
Enter a numeric value.
NOTE
If one of the center X coordinate and center Y
coordinate exceeds the feedback range, an alarm
is issued. If the error of the other coordinate is
within the feedback range in this case, the data is
not set as a workpiece origin offset value.
If one of the center X coordinate and center Y
coordinate is within the feedback range, the data is
set in the workpiece coordinate system. If the error
of the other coordinate is within the OK range, the
data is not set as a workpiece origin offset value.
If one of WORK COORD. VALUE X and WORK
COORD. VALUE Y is not entered, the data of the
axis is not checked for an error, and is not set as a
workpiece origin offset value.
The descriptions of the other items are the same as for "X-AXIS
DIRECTION WORK SETUP (PROBE Z-AXIS)".
Processing when the OK range and the feedback range are 0
The same processing as for "X-AXIS DIRECTION WORK SETUP
(PROBE Z-AXIS)" is performed.