B-63874EN-1/02 2.MEASUREMENT CYCLE
- 113 -
Processing when the OK range and the feedback range are 0
When the Ok range and the feedback range are set to 0, the processing
below is performed.
<1> When both the OK range and the feedback are set to 0
The result of measurement is not set in the setting destination.
Moreover, no alarm is issued as a result of measurement. (The
result of measurement is just recorded in the measurement result
list.)
<2> When the OK range is set to 0, and the feedback range is set to a
nonzero value
If an error obtained from measurement is within the feedback
range, the result of measurement is set in the setting destination.
If an error obtained from measurement exceeds the feedback
range, an alarm is issued.
<3> When the OK range is set to a nonzero value, and the feedback
range is set to 0
An alarm is issued.