Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-3
Page
FANUC LTD.
12
64
The following measurements are improved in MEASURE menu.
Outside Diameter Measurement (PROBE Z-AXIS DIRECTION)
Inside Diameter Measurement (PROBE Z-AXIS DIRECTION)
Outside Diameter Measurement (PROBE X-AXIS DIRECTION)
Inside Diameter Measurement (PROBE X-AXIS DIRECTION)
Data Entry Window (Stylus Ball Diameter Measurement (PROBE Z-AXIS DIRECTION))
MEASURE
Input Item Meaning
Q MEASUREMEN
T COND.
Measurement Conditions Group Number
D BASE WORK
RADIUS
Diameter of the reference work piece
H APROCH
CENTER PT. X
X Coordinate value of the center of the reference work
piece
V APROCH
CENTER PT. Y
Y Coordinate value of the center of the reference work
piece
L HEIGHT OF
MEAS. PT.
Height of a measurement point in the Z-axis direction.
R APROCH
DISTANCE
Move distance from the approach point to the
measurement point in the Z-axis direction.
N STARTING
ANGLE
Positioning angle when the first point is measured.
0° is displayed as a default value.
M PITCH ANGLE Pitch angle between each measurement points.
90° is displayed as a default value.
F MOVING
MEAS. SPEED
Feed rate for measurement
P MEASUREMEN
T POINT
Number of measurement points(3 or 4).
SET
Input Item Meaning
S OK RANGE (±) Allowable range of errors obtained from measurement.
Y FEED BACK
RANGE (±)
If an error obtained from measurement is not within
the OK range but is within this feedback range, the
measured value is set in the setting destination. If an
error obtained from measurement exceeds the feedback
range, an alarm is issued.