2.MEASUREMENT CYCLE B-63874EN-1/02
- 252 -
2.10 SETTING OF A RANGE FOR DISABLING FEEDBACK
Even if the results of measurements lie within a specified feedback
rang in a measurement cycle of a machining program, the feedback
capability can be disabled.
In this case, however, the results of measurements are recorded in a
measurement result list.
Setting the feedback mode to ON/OFF
In the range specified by the four-digit G codes indicated below,
feedback operation is disabled even if the results of measurements lie
within the feedback range after measurement cycle execution.
G2090 Feedback mode OFF
G2091 Feedback mode ON
NOTE
At the time of power-on or reset, the feedback mode
is ON.
Example of use
O2999
;
G2003Q5.D30.H0.V0.L-10.R20.F10.S0.003Y1. ;
;
G2090;
;
G2040P1.Q5.H100.V0.L-10.R20.F10.W7.I2.
S0.005Y1.U7.J4.K0.005E1. ;
G2040P1.Q5.H-100.V0.L-10.R20.F10.W7.I2.
S0.005Y1.U7.J4.K0.005E1.;
G2040P1.Q5.H120.V50.L-10.R20.F10.W7.I2.
S0.005Y1.U7.J4.K0.005E1.;
;
G2091;
;
In this range,
feedback operation
is disabled.