Ed.
Date
Design
Description
Name
Draw.
FANUC MANUAL GUIDE i
(Series16i/18i/21i-MB/TB)
OPERATOR’S MANUAL
B-63874EN-1/02-3
Page
FANUC LTD.
64
64
cycle or selection screen of manual measurement.
0: Undisplay
1: Display
CNR Display / Undisplay the angle of inside / outside corner
measurement
cycle.
0: Undisplay
1: Display
NOY Display / Undisplay the measurement cycle of Y-axis, and input data of
Y-axis direction.
0: Display
1: Undisplay
#7 #6 #5 #4 #3 #2 #1 #0
27224 #5 #1 #0
#0 The input item APROACH DISTANCE on the data entry window of
measurement cycle
0 : Display
1 : Not display
#1 The input OK RANGE and FEED BACK RANGE on the data entry
window of measurement cycle
0 : Display
1 : Not display
#5 The input item MEASURE CONDITION
0 : Display.
1 : Not display. The group number of measurement condition
is selected always 1.
#7 #6 #5 #4 #3 #2 #1 #0
27225 #6 #5
#5 STYLUS OFFSETS CALIBRATION-A
0 : Display
1 : Not display
#6 STYLUS OFFSETS CALIBRATION-B
0 : Display
1 : Not display
#7 #6 #5 #4 #3 #2 #1 #0
27226 #5 #4
#4 Concerning to the MEAURE PLANE of manual measurement,
0 : It is possible to select between others measurement planes.