APPENDIX 3 ERROR MESSAGES
Message
Description and action to be taken
STACK REGISTER OVER (8bit) ERR - There are 9 or more continuous stacks in the
LADDER program which was read in.
NOT EXIST APPOINT DATA SIZE
- There is not enough data area for the specified file.
FILE NOT READ
- Disk space insufficient during writing
DISK SPACE NOTHING
- Error occurred when reading data from a file.
FILE NOT WRITE
- Error occurred when writing data to a file.
INSUFFICIENT MEMORY. HIT ANY - Area to be used in editing could not be acquired.
KEY!
3.2 Other Editing (Applicable to Title, Message, System Parameter, Symbol
and Comment, and I/O Module Editing)
Message
File Read Error! Hit Any Key
File Write Error! Hit any Key
File I/O Error! Hit Any Key
Not Enough Space
Same Symbol Data Exist
No Definition Address Appointed
Data Save Error
Not Found Data Error
Input Data Invalid
Appointed group Not Exist
Appointed Base Not Exist
Appointed Slot Not Exist
Appointed ID Code Not Exist
Input Key Not Used
Invalid Address Appoint
Description and action to be taken
- File could not be read.
- File could not be written.
- File I/O error occurred.
- Work area for message editing could not be
acquired due to insufficient memory.
- Symbol data already exists that is identical to
symbol data that was input.
- Nonexistent address was specified.
- Error occurred when symbol or comment data was
being registered in the work area.
- Required data could not be found during symbol
data lookup.
- There is an input error in the l/O module settings.
- There is an error in the group that was input.
- There is an error in the base that was input.
- There is an error in the slot that was input.
- There is an error in the ID code that was input.
- Undefined key was specified.
- Specified address could not be found during
search.
Invalid Value
Operate Panel Address Error
- Out-of-bound value was input.
- Data other than a numeric value was input.
- Addresses have not been set at the operation
panel.
A3-5