3.CREATING AND EDITING SEQUENCE PROGRAMS B-63484EN/05
- 80 -
3.3.20 Changing Signal Addresses and Function Instruction
Parameters in the Display Window
This subsection describes how to change signals addresses and
function instruction parameters in the display window.
Procedure
1 Position the cursor to the signal address or function instruction
parameter you want to change.
2 Press and hold down the [Shift] key and press the [Enter] key,
and the address or parameter will enter the change-enabled state.
(You can also key in directly after positioning the cursor.)
Fig. 3.3.20
3 Change the signal address or function instruction parameter, and
press the [Enter] key.
NOTE
1 You can also enter a symbol as a signal address.
2 You cannot change function instruction numbers or
the first parameters of the function instructions
ADDB, AND, COMPB, DIVB, EOR, MULB, OR,
and SUBB.