B.CONVERSION USING A SIGNAL ADDRESS CONVERTER APPENDIX B-63484EN/05
- 414 -
B CONVERSION USING A SIGNAL
ADDRESS CONVERTER
Table B
Converter file name Applicable function Reference document
FS0T_CNV.SYM PMC-L/M/M(MMC)
(FS0-T)
→ PMC-SA1/SA3/SB3/SC3/
SB4/SC4/SB5/SB6
(FS16/18/20-T)
FS0M_CNV.SYM PMC-L/M/M(MMC)
(FS0-M)
→ PMC-SA1/SA3/SB3/SC3/
SB4/SC4/SB5/SB6
(FS16/18/20-M)
PM-C_CNV.SYM PMC-P
(Power Mate-MODEL C)
→ PMC-PA3
(Power Mate-MODEL D/F/H)
FANUC PMC-MODEL
PA1/PA3/SA1/SA2/SA3/SB/
SB2/SB3/SB4/SB5/SB6/SB7/
SC/SC3/SC4/NB/NB2/NB6
Programming Manual
(Ladder Language)
B-61863E
The converter files are stored in the subdirectory \APPENDIX of the
system floppy (Vol. 5).
Example of operation: PMC-P → PMC-PA3
<1> By using Ladder Editing Package (Windows), convert a program
of the PMC-P model (conversion source) to a mnemonic file. (A
in the figure below)
<2> By using Ladder Editing Package (Windows), create a program
of the PMC-PA3 model (conversion destination).
<3> Convert the program of <2> to mnemonics. (B in the figure
below)
<4> Start a text editor commercially available, then open the
mnemonic file (conversion destination) created in <3>.
<5> Replace the symbol data of the mnemonic file (conversion
destination) with the converter file. (C in the figure below)
<6> Replace the ladder data of the mnemonic file (conversion
destination) with the ladder data of the mnemonic file
(conversion source) created in <1>. (D in the figure below)
<7> Close the mnemonic file (conversion destination) on the text
editor.
<8> By using Ladder Editing Package (Windows), convert the
mnemonic file (conversion destination) of <7> to a source
program (with the program created in <2> left open).
<9> Delete all symbol comment data.