B-63484EN/05 3.CREATING AND EDITING SEQUENCE PROGRAMS
- 145 -
1-1 Set the necessary data.
Counter Data Type
Initial value: BINARY
Set the format of the counter value to be used in the
CTR function instruction as binary or BCD.
Ladder Exec
(Valid only with the PMC-SC3/SC4, PMC-QC,
PMC-NB/NB2, and PMC-SB7)
Initial value: 100
Setting: 1 to 150
Set an increment for the processing time for ladder
levels 1 and 2. Setting this parameter reduces the
ladder scan time, thus quickening ladder processing.
The ladder execution time takes the value described
below out of 8 ms.
If 100% is specified, the processing time for levels 1
and 2 is 5 ms.
If 150% is specified, the processing time for levels 1
and 2 is 7.5 ms.
Note that increasing the ladder execution time
decreases the processing time in "PMC Screen Display
Time", "Language Program Processing Time", and
"Ladder Level 3".
Language Exec Ratio
(Valid only with the PMC-SC3/SC4, PMC-QC, and
PMC-NB/NB2)
Initial value: 50
Setting: 0 to 99
This parameter sets a ratio for dividing the processing
time in "PMC Screen Display Time", "Language
Program Processing Time", and "Ladder Level 3",
because the language program and the PMC screen
display have the same priority.
Setting this parameter makes it possible to run the
language program cyclically, even when the PMC
screen display is active.
Language Origin
(Valid only with the PMC-SC3/SC4, PMC-QC, and
PMC-NB/NB2)
Initial value: 000000
Setting: Address within the language program
storage area
Set the start address of the link control statement data
in the language program.
Specify 000000H if no language program is included.