B-63484EN/05 3.CREATING AND EDITING SEQUENCE PROGRAMS
- 129 -
Table 3.5.1 (c)
Net comment
Usable characters ASCII characters, kana, kanji, half-size kana
Number of usable steps 2 steps/net comment
Maximum number of
characters
64 bytes/line or 4095 bytes/net comment
Maximum number of lines 100 lines/net comment
Maximum number of units
that can be registered
Approx. 20,000
(2) PMC model which supports the multiple comments
Table 3.5.1 (d)
Definition Display
Symbol
Character string assigned to a
contact or coil (on a one-to-one
basis) and used in place of a PMC
address
Comment
(for a contact and a coil)
Character string assigned to a
contact and a coil to describe it.
One of comment sets is displayed.
Net comment
Assigned to an arbitrary position
between nets to describe the
program
Table 3.5.1 (e)
Symbol Coil comment
Usable characters
ASCII characters (except
lowercase letters)
ASCII characters
Kana and kanji
Half-size kana
Maximum number of
characters
16 bytes 30 bytes
Maximum number of units
that can be registered
40,000 40,000
Duplicate definition Not allowed Allowed
Table 3.5.1 (f)
Net comment
Usable characters ASCII characters, kana, kanji, half-size kana
Number of usable steps 2 steps/net comment
Maximum number of
characters
64 bytes/line or 4095 bytes/net comment
Maximum number of lines 100 lines/net comment
Maximum number of units
that can be registered
Approx. 20,000
INPUT
X0.0 Y0.0
1st comment
of contact
1st OMMENT
of coil
(* HERE IS NET *)
* COMMENT *