9.DIAGNOSIS B-63484EN/05
- 318 -
9.7.8 [Gridline Format] Screen
When [Gridline Format] is selected from the context menu, the
[Gridline Format] screen appears.
Fig. 9.7.8
Line Color
Choose from the following 16 colors:
Black, blue, light blue, light green, pink, red, yellow, white, dark
blue, peacock blue, green, purple, dark red, dark yellow, 50%
gray, 25% gray
Line Style
Solid line, dotted line, or broken line
Scale
When the sampling interval is 8 msec:
8 msec, 16 msec, or 32 msec
When the sampling interval is 4 msec:
4 msec, 8 msec, or 16 msec
When the trigger mode is ONLY:
1 time, 2 times or 4 times
To reset the settings to the defaults, click the <RESET> button.
Table 9.7.8
Default
Line Color 50% gray
Line Style Solid line
Scale 8 msec (4 msec, 1 times)
9.7.9 Automatic Signal Sampling Function at Power-On
If sampling parameters are set, then [Signal Analysis Start] is checked
on the [Set Up] screen for PMC parameters, sampling will start
automatically when the power to the CNC is turned on.