B-63484EN/05 12.ERROR MESSAGES
- 393 -
Error code Message Cause/action
E:E-6090 RELAY OR COIL FORBIT An unnecessary relay or coil is set. Delete the relay or coil.
E:E-6092 HORIZONTAL LINE ILLEGAL Connect the horizontal line of the net.
E:E-6093 FUNCTION LINE ILLEGAL Connect the function instruction correctly.
E:E-6094 RELAY OR COIL NOTHING A relay or coil is missing. Add a relay or coil.
E:E-6095 VERTICAL LINE ILLEGAL Connect the vertical line of the net.
E:E-6096 PARAMETER NOTHING
The parameters of a function instruction are missing. Set the
parameters.
E:E-6097 ADDRESS NOT DETECTED Set an address.
E:E-6100 NET TOO LARGE
The net being edited has become larger than the edit buffer.
Reduce the size of the net being edited.
E:E-6101 PLEASE COMPLETE NET
E:E-6102 LARGE NET APPEARED Reduce the size of the net.
E:E-6111 ERROR NET FOUND Modify the error net.
E:E-6115 PARA NO. RANGE ERR
E:E-6130 There is no CE instruction. Although the functional instruction CS is used, there is no
functional instruction CE that means the end.
E:E-6131 **** instruction can not be used excluding
the 2nd level main program.
Use the functional instruction **** in the LEVEL2 or the
subprogram.
E:E-6132 **** instruction can not be used in the
range controlled COM instruction.
Do not use functional instruction **** between COM and COME.
E:E-6133 Another CS instruction can not be used in
the range of CS instruction.
Use CS and CE in a pair. And don’t nest a pair of CS and CE.
E:E-6134 CM instruction must be used between CS
and CE instruction.
Use functional instruction CM between CS and CE
E:E-6135 CE instruction must be used in CS
instruction and a pair.
Use CS and CE in a pair. And don’t nest a pair of CS and CE.
E:E-6136 Use only CM instruction between CS and
CE instruction.
Do not use other instructions except the functional instruction CM
between CS and CE.
E:E-6150 Ladder diagram has not been modified.
The ladder diagram is not modified, but an attempt was made to
update or restore it.
E:E-6152 Ladder data write error.
E:E-6154 Temporary file load error.
E:E-6155
Program read error.
Not enough program memory.
Allocate conventional memory.
E:E-6156
Program read error.
Error status = ****
E:E-6160 The program is not corresponding
A selected program does not match the program in PMC
memory. By specifying, loading, or by storing a correct program,
ensure a match with the program in PMC memory.
The online edit/input/output function (sequence program
load/store) is protected. Check the keep relay.
E:E-6183 This function is protected.
Display of the data table control screen is protected. Check the
keep relay.
E:E-6187 Write protect. The signal status is write-protected. Check the keep relay.
E:E-6197 INPUT NET TOO LARGE
E:E-6362
Ladder diagram on the PMC side is being
edited now.
E:E-6701
The type of symbol specified as basic
instruction is erroneous.
E:E-6702
The output prohibition symbol was
specified as the coil.