9.DIAGNOSIS B-63484EN/05
- 316 -
Sampling Time
Set the maximum sampling time.
When the sampling interval is 8 msec, set 1 to 10 sec (in 0.1-sec
increments).
When the sampling interval is 4 msec, set 1 to 5 sec (in 0.1-sec
increments).
Trigger Address
Set the trigger bit address at which sampling starts, with a PMC
address or symbol.
Condition
Condition for starting sampling
Start: Sampling start button on the toolbar
Trigger-ON: Sampling start button + rising edge at the trigger
address
Trigger-OFF: Sampling start button + falling edge at the trigger
address
NOTE
When Trigger-ON or Trigger-OFF is selected with
no trigger address set, a message box appears,
indicating "No Trigger Address."
Trigger Mode
There is a buffer for holding data sampled for up to 10 seconds
when the signal status is read at 8-msec intervals. (When the
signal status is read at 4-ms intervals, the buffer can hold data
sampled over five seconds.)
In trigger mode, the read start and end points are specified.
After: The signal status after the trigger address meets the
trigger condition is read until the sampling time elapses.
About: The signal status around the time at which the trigger
address satisfies the trigger condition is read within the
sampling time.
Before: The signal status from when the <Sampling> button on
the tool bar is pressed until the trigger address satisfies
the trigger condition is read for up to the sampling time.
Only: The signal status when the trigger address satisfies the
trigger condition is read.
NOTE
When About or Before is selected with the
condition set to Start, a message box appears,
indicating "[About]/[Before] is illegal on [Start]
selected."
Signal Address
Set up to 16 sampling addresses with PMC addresses or symbols.