9.DIAGNOSIS B-63484EN/05
- 314 -
<6> Symbol on/off
Sets the display format of the trigger and sampling addresses.
When the symbol format is selected, the button is in the down
state; when the address format is selected, the button is in the up
state.
<7> Search
Moves through the signal analysis area with a specified search
time.
<8> Text box for inputting the character string for which a search is
to be made
Specifies the search time.
<9> Search character string increase/decrease button
Increases or decreases the search time in grid setting time units.
9.7.3 Status Bar
Fig. 9.7.3
<1> to <6> are displayed when sampling terminates.
During sampling, [Executing] is indicated.
<1> Sampling time
<2> Condition
<3> Trigger mode
<4> Trigger address
<5> Sampling start time
<6> Sampling end time
<7> The current mouse position is indicated as the time (msec) on the
signal analysis display.
9.7.4 Context Menu
Fig. 9.7.4
<1> <2> <3> <4> <5> <6> <7>