12.ERROR MESSAGES B-63484EN/05
- 400 -
Error code Message Cause/action
J:F-2104 **** Memory card format file read error.
The memory card format file **** could not be read. The file is
invalid.
J:F-2105 **** source program write error. The source program **** could not be written.
J:E-3100 There is an undefined instruction.
An instruction that cannot be handled by a selected type of
program, or a destroyed instruction is included.
J:E-3101
There is no SPE instruction at the bottom
of the subprogram.
A sub-program in a selected program does not end with the SPE
instruction.
J: E-3200
The number of symbol data in source
program exceeds the limit.
The number of symbol data items in a selected program
exceeded the maximum allowable value defined with the system.
Reduce the number of symbol data items.
J:E-3300 ID code (I/O module) error.(address ****)
The ID code defined at address **** in the I/O module data
cannot be recognized correctly. Prepare a correct memory card
format file.
J:W-4100
The size of LADDER program is too
large.
The number of steps of a sub-program in a ladder program
exceeded the maximum allowable value of a selected type of
program, but the sub-program is output to the source program.
Make corrections by ladder editing as required.
J:W-4101
**** unused NET COMMENT pointer
found.
**** net comment pointers not corresponding to net comment
character strings were detected. The net comment pointers are
not output to the source program. Make corrections by ladder
editing as required.
J:W-4102
**** unused NET COMMENT strings
found.
**** net comment character strings not corresponding to net
comment pointers were detected. The net comment character
strings are deleted. Make corrections by ladder editing as
required.
J:W-4103
**** duplicated NET COMMENT pointer
found.
**** duplicate net comment pointers were detected. Character
strings are copied so that the same net comment character string
corresponds to the same net comment pointer.
J:W-4104
The step number of **** is used twice or
more.
The same step number **** is used for different steps. Make
corrections by step sequence editing.
J:W-4105
Some sub-programs are protected. These
sub-programs have not been decompiled.
J: W-4200
The number of symbol data exceeds the
limit.(address, symbol)
During symbol data merge processing, the total number of data
items at address ****/symbol **** exceeded the maximum
allowable value defined with the system. Data beyond the symbol
data is not output to the source program.
J:W-4201
**** symbol data at duplicated address
found.
**** duplicate symbol data items defined for the same address
were detected. Either source data or memory card data is valid
according to the setting of the symbol merge option.
J:W-4202
Same symbol exists.(address **** symbol
****)
The symbol character string defined in the symbol data at
address ****/symbol **** is already defined at another address.
The symbol data is not output to the source program.
J: W-4203 Illegal symbol.(address, symbol)
The symbol data at address ****/symbol **** is determined to be
invalid by a symbol character string check based on the IEC
standard. The symbol data is not output to the source program.
If the check option in the %%%FLSET.CNF setting file is
deselected, the symbol data is output to the source program.
J: W-4204 Symbol data address illegal.(symbol)
The address in the symbol data containing symbol **** cannot be
recognized correctly. The symbol data is not output to the source
program.
J:W-4300
Illegal operator panel (system parameter).
Proceed to decompile using 'NO'.
The specification of an operator's panel in the system parameter
data is invalid. Execution is continued, assuming that the
specification of the operator's panel is invalid.