B-63484EN/05 12.ERROR MESSAGES
- 389 -
Error code Message Cause/action
A:E-3144 Cannot close file The **** file cannot be closed.
A:E-3145 File I/O error A file access error occurred.
A:E-3146 **** file I/O error
A:E-3147 Unknown PMC series
A:E-3148 **** file write error. Hit any key. The **** file cannot be written to.
A:E-6000 Illegal folder name Specify an existing folder as the export destination for a user file.
A:E-6001 PMC type is different
When an LAD file is imported, the PMC model of the import
source must match that of the open program.
A:E-6002 Export Ladder File is protected Deselect the ladder file from export targets.
A:E-6003 Import Ladder File is protected Deselect the ladder file from import targets.
A:E-6004 Export Sub program File is protected Deselect the sub-program file from export targets.
A:E-6005 Import Sub program File is protected Deselect the sub-program file from import targets.
A:E-6006 Fail to delete file
Check whether the file you attempt to delete is used with another
system.
A:W-7000
Net comment can be selected when all
data is selected
Select all the data files, ladder diagrams, and sub-programs to
import a net comment.
A:W-7001 No timer available
Since the timer cannot be used, the status bar display cannot be
updated. Ladder Editing Package (Windows) can be executed
normally.
12.2.2 Title Editing
Error code Message Cause/action
B:E-3020 File read error. Hit any key The title file (TITLE) of a source program cannot be read.
B:E-3021 File write error. Hit any Key
The title file (TITLE) or control file (CONTROL) of a source
program cannot be written to.
B:E-3022 File I/O error. Hit any key A file access error occurred.
12.2.3 I/O Module Editing
Error code Message Cause/action
C:E-3021 File read error. Hit any key
The I/O module file (IOMODULE) of a source program cannot be
read.
C:E-3022 File write error. Hit any key
The I/O module file (IOMODULE) or control file (CONTROL)
cannot be written to.
C:E-3023 Input data invalid Check the input method.
C:E-3024 Appointed Group not exist Check the input range.
C:E-3025 Appointed Base not exist Check the input range.
C:E-3026 Appointed Slot not exist Check the input range.
C:E-3027 Appointed ID Code not exist The entered module does not exist. Check the usable modules.
C:E-3028 Input key not used
C:E-3030 Address appoint illegal
This address does not allow the entered module to be used.
Check if an output module is entered in address X, or if an input
module is entered in address Y.
C:E-3032
The same group base and slot are
already specified
A module is already set in the entered group, base, and slot. The
same group, base, and slot cannot be set more than once.
Specify a different group, base, or slot.
C:E-3033 Invalid Channel No. appoint Check the usable channels.
C:E-3034
Invalid data except '0' is specified at the
slot of * as I/O UNIT B
I/O Unit-B (power-on/off information) can be set in slot 0 only.
Reenter by specifying slot 0.
C:E-6011 Not Module