15. PMC CONTROL FUNCTION
B–64113EN–1/01
1048
NOTE
1 When this parameter is set, the power must be turned off
before operation is continued.
2 If 0 or a value beyond the valid data range is set in this
parameter, this parameter becomes invalid.
Number Message Description
059 PROGRAM NUMBER
NOT FOUND
In an external program number search
or external workpiece number search,
a specified program number was not
found. Otherwise, a program specified
for searching is being edited in back-
ground processing. Check the program
number and external signal. Or discon-
tinue the background eiting.
131 TOO MANY EXTERNAL
ALARM MESSAGES
Five or more alarms have been gener-
ated in external alarm message.
Consult the PMC ladder diagram to find
the cause.
132 ALARM NUMBER NOT
FOUND
No alarm No. concerned exists in exter-
nal alarm message clear.
Check the PMC ladder diagram.
133 ILLEGAL DATA IN EXT.
ALARM MSG
Small section data is erroneous in ex-
ternal alarm message or external oper-
ator message. Check the PMC ladder
diagram.
Alarm and Message