B–64113EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
474
#7
F104
#6 #5
NOINPS
#4 #3 #2 #1 #0
CNC→PMC
#7
G359
#6 #5 #4 #3
NOINP4
#2
NOINP3
#1
NOINP2
#0
NOINP1
#7
1601
#6 #5
NCI
#4 #3 #2 #1 #0
[Data type] Bit
NCI In–position check at deceleration
0 : Performed
1 : Not performed
#7
8007
#6 #5 #4 #3 #2 #1 #0
NIS
[Data type] Bit
NIS In the in–position check of PMC axes, in–position check disable signal
NOINPS <G023#5> and in–position check disable signals for individual
axes NOINP1 to NOINP4 <G359#0 to #3> are:
0 : Invalid.
1 : Valid.
NOTE
1 Although in–position checks of ordinary blocks can be
disabled by using in–position check disable signal NOINPS
<G023#5> and in–position check disable signals for
individual axes NOINP1 to NOINP4 <G359#0 to #3> , the
in–position check at the reference position obtained by a
reference position return operation (G28 or G30) is always
performed. The in–position check at an intermediate point,
however, can be disabled.
2 When the in–position check disable signals for individual
axes NOINP1 to NOINP4 <G359#0 to #3> are used,
PMC–SB7 is necessary.
Siganl address
Parameter
Note