3. MANUAL OPERATION
196
Incremental feed mode
(TEACH IN HANDLE mode)
Reset
+J1
1st axis move
+J1 is inef-
fective dur-
ing this
period.
Axis is fed again
after signals have
turned to “0” once.
Move is stopped by
resetting
[Classification] Input signal
[Function] Selects a feedrate in jog feed or incremental feed. These signals are in
sixteen bit binary code, which corresponds to the override values as
follows:
Override value (%) = 0.01%
ȍ
15
i + 0
|2
i
Vi |
where
Vi = 0 when the *JVi signal is “1”
Vi = 1 when the *JVi signal is “0”
The override value is assumed to be zero when all of the signals, (*JV0
to *JV15) are set to “1” or “0”. When this occurs, the feed is stopped.
The override value can be specified in the range of 0% to 655.34% in units
of 0.01%. Some examples are listed below.
*JV0 – *JV15
12 8 4 0
(%)
1111
1111
1111
1111
1111
1101
0110
0000
0000
1111
1111
1111
1111
1100
1000
0011
0000
0000
1111
1111
1111
1001
0001
1110
1011
0000
0000
1111
1110
0101
1011
0111
1111
1111
0001
0000
0
0.01
0.10
1.00
10.00
100.00
400.00
655.34
0
[Operation] If rapid traverse selection signal RT is “0” during jog feed or incremental
feed, the manual feedrate specified by parameter (No. 1423) is overridden
by the value specified by the JVi signal.
NOTE
The JVi signals also serve as the override signals during dry
run in automatic operation mode.
Manual Feedrate
Override Signal
*JV0 – *JV15
<G010, G011>