12. DISPLAY/SET/EDIT
B–64113EN–1/01
806
To deselect a signal type, reset the related parameter to 0 (the address and
bit combined with the parameter that is reset are reset simultaneously with
that parameter). When a signal type is specified, the parameter for setting
the address to be combined and the parameter for setting the bit are
initialized to 0.
Example) If parameter No. 12801 is 3, parameter Nos. 12841 and 12881
are initialized, respectively, to 0 and 00000000.
If an attempt is made to specify an invalid value, the warning message
”Data out of range” is displayed; so, you should retry.
12841 Operation history signal selection address (No. 01)
12842 Operation history signal selection address (No. 02)
12843 Operation history signal selection address (No. 03)
::
12860 Operation history signal selection address (No. 20)
[Data type] Word
[Valid data range] 0 to 255
Set up addresses for operation history signal selection. Setting up an address
causes the parameter for setting the bit combined with that address to be
initialized to 0. If an attempt is made to set an invalid value, or the parameter
for setting the parameter type combined with that address is 0, the warning
message ”Data out of range” is displayed; so, you should retry.
#7
12881
#6 #5 #4 #3 #2 #1 #0
(No. 01)
12882 (No. 02)
12883 (No. 03)
::
12900 (No. 20)
[Data type] Bit
Set or reset bits for operation history signal selection. To select a signal
as a history target, set the related bit to 1. Otherwise, reset it to 0. If the
parameter for setting a signal type combined with that bit is 0, the warning
message ”Data out of range” is displayed; so, you should retry.