12. DISPLAY/SET/EDIT
B–64113EN–1/01
804
Example:To select the automatic operation start signal (G7.2) as
operation history target No. 2, set up the related parameters as
listed below:
No.12802=1
No.12842=7
No.12882=00000100
If parameter No. 12802 is 1, parameter Nos. 12842 and 12882
are initialized to 0. If parameter No. 12842 is 7, parameter No.
12882 is initialized to 0. Be sure to set parameter Nos. 12802,
12842, and 12882 in the stated sequence.
CAUTION
A parameter clear operation (turning the power on with the
<RESET> key held) down does not deselect signals from
operation history targets. To deselect them, perform a
release operation ([DELET] or [ALLDEL] soft keys) on the
”operation history signal selection screen” or, when bit 4 of
parameter No. 3206 is 1, reset parameter Nos. 12801 to
12820 to 0.
#7 #6 #5 #4 #3 #2 #1 #0
OHS3106 OHD
[Data type] Bit
OHD The operation history screen is:
0 : Not displayed.
1 : Displayed.
OHS Operation history sampling is:
0 : Performed.
1 : Not performed.
NOTE
Normally, set 0 (sampling is performed).
#7
3112
#6 #5
OPH
#4 #3 #2 #1 #0
NOTE
CNC power must be cycled for this perameter to take effect.
OPH Enable the operation history function.
0 : Enabled.
1 : Disabled.
Caution
Parameter