13. INPUT/OUTPUT OF DATA
B–64113EN–1/01
916
(1)Program input/output
(a) Program input
· When the data input/output function based on the I/O Link
is used
1) Specify a number between 20 to 35 as the I/O channel
on the setting screen to specify a group number.
2) Specify EDIT mode.
3) Display the program screen with function key
PROG
.
4) To change the program numbers, enter a new program
number as follows:
(i) Select address O.
(ii) Key in the new program number.
5) Using soft keys [(OPRT)], continuous–menu key
, [READ], and [EXEC], read the program.
· When data input/output function B based on the I/O Link is
used
1) To read programs without changing the program
numbers, specify –9999. To read programs by changing
the program numbers, specify a desired number with the
PMC function instruction (WINDW). A program
number thus specified serves as the first program
number when multiple programs are received. The
second and any additional programs are numbered
sequentially starting with the first number.
2) Specify a desired group number with group number
specification signals SRLNI0 to SRLNI3.
3) Select an I/O Link by setting I/O Link specification
signal IOLS to 1.
4) When external punch start signal EXRD is set to 1,
programs are read from the power mate CNC.
NOTE
The user cannot read a program having an arbitrary
program number registered in a power mate CNC. All
programs are always read from a Power Mate.
(b) Program output
· When the data input/output function based on the I/O Link
is used
1) Set a number between 20 and 35 as the I/O channel on
the setting screen used to specify a group number.
2) Set EDIT mode.
3) Display the program screen by pressing the function
key
PROG
.
4) Select address O.
D Basic data input/output
procedure