B–64113EN–1/01
11. PROGRAM COMMAND
751
MPR Custom macro interrupt valid/invalid M code
0 : M96/M97
1 : M code set using parameters (Nos. 6033 and 6034)
MSB Interrupt program
0 : Uses a dedicated local variable (Macro–type interrupt)
1 : Uses the same local variable as in the main program (Subprogram–
type interrupt)
MCY Custom macro interrupt
0 : Not performed during cycle operation
1 : Performed during cycle operation
MUS Interrupt–type custom macro
0 : Not used
1 : Used
6033 M code that validates a custom macro interrupt
6034 M code that invalidates a custom macro interrupt
[Data type] Byte type
[Valid data range] 0 to 255
These parameters set the custom macro interrupt valid/invalid M codes.
NOTE
These parameters can be used when MPR, #4 of parameter
No. 6003, is 1. M96 is used as a valid M code and M97 is
used as an invalid M code when MPR is 0, irrespective of the
state of this parameter.
NOTE
1 No interrupt–type custom macro can be used during DNC
operation.
2 No interrupt–type custom macro can be used during
multiple repetitive canned cycle execution.
D Setting M code that
makes interruption
effective and ineffective
Note