B–64113EN–1/01
5. AUTOMATIC OPERATION
313
#7 #6 #5 #4 #3 #2 #1 #0
5200 DOV
[Data type] Bit
DOV For tool extraction during rigid tapping, override is:
0 : Disabled.
1 : Enabled. (The override value is set in parameter No.5211 or
No.5381.)
#7
5202
#6 #5 #4 #3 #2 #1
RG3
#0
[Data type] Bit
RG3 Rigid tapping retraction is performed using:
0 : Input signal RTNT <G62#6>
1 : One–shot G code G30 command
NOTE
1 When this parameter has been set, the power must be
turned off before operation is continued.
2 When this parameter is to be set to 1, be sure to set bit 0
(G84) of parameter No. 5200 to 0.
5381 Override for rigid tapping retraction
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 200
Sets an override value to be applied to rigid tapping retraction. No
override is applied if 0 is set.
NOTE
1 This parameter is valid when bit 4 (DOV) of parameter No.
5200 is set to 1.
2 If bit 3 (OVU) of parameter No.5201 is set to 1, 10% is set
as the units of data. Thus, an override of up to 2000% can
be applied during extraction.
5382 Retract value α for rigid tapping return
[Data type] 2–word
[Unit of data] Input increments
[Valid data range] 0 to 99999999
Sets an extra retract value for rigid tapping retraction. The tool will be
pulled beyond the R point by α. If rigid tapping retraction has already
been completed, the tool is pulled by α only.
Parameter