B–64113EN–1/01
12. DISPLAY/SET/EDIT
831
#7 #6 #5 #4 #3 #2 #1 #0
OUT7F072 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0
F073 ZRNO MD4O MD2O MD1O
F074
SPOF075 KEYO DRNO MLKO SBKO BDTO
F076 ROV2O ROV1O MP2O MP1O
F077 RTO HS1DO HS1CO HS1BO HS1AO
*FV7OF078 *FV6O *FV5O *FV4O *FV3O *FV2O *FV1O *FV0O
*JV7OF079 *JV6O *JV5O *JV4O *JV3O *JV2O *JV1O *JV0O
*JV15OF080 *JV14O *JV13O *JV12O *JV11O *JV10O *JV9O *JV8O
–J4OF081 +J4O –J3O +J3O –J2O +J2O –J1O +J1O
#7 #6 #5 #4 #3 #2 #1 #0
7200 OP7 OP6 OP5 OP4 OP3 OP2 OP1
[Data type] Bit
OP1 Mode selection on software operator’s panel
0 : Not operational
1 : Operational
OP2 JOG feed axis select and manual rapid traverse buttons on software
operator’s panel
0 : Not operational
1 : Operational
OP3 Manual pulse generator’s axis select and manual pulse generator’s
magnification switches on software operator’s panel
0 : Not operational
1 : Operational
OP4 JOG feedrate override and rapid traverse override switches on software
operator’s panel
0 : Not operational
1 : Operational
OP5 Optional block skip, single block, machine lock, and dry run switches on
software operator’s panel
0 : Not operational
1 : Operational
OP6 Protect key on software operator’s panel
0 : Not operational
1 : Operational
Signal address
Parameter