12. DISPLAY/SET/EDIT
B–64113EN–1/01
856
f Menu screen (machine maintenance only)
G10 L61 P01 [n] ;
G10 L61 P02 [n] ;
G10 L61 P03 [n] ;
:
a : Service life
r : Remaining lifetime
n : Item name
[Alphanumeric character]
q : Count type
0 = No counting.
1 = Nonstop counting.
2 = Counting continues as long as the power is on.
3 = Counting continues throughout run time.
4 = Counting continues throughout cutting time.
In EDIT mode, pressing the [READ] soft key causes input data to be
registered according to a specified format (G10). Registration is possible
even if the format (G10) is already in program memory as long as the
programmable data input option is available.
NOTE
Registration may not be performed correctly unless the
input format (G10) matches the output format.
[Classification] Output signal
[Function] This signal indicates whether the service life of consumable parts (that
need periodic replacement) specified on the periodic maintenance screen
has expired.
The signal is valid only when items to be subjected to maintenance have
been specified.
[Operation] The signal becomes ”1” when:
· The service life of one or more consumable parts that need periodic
replacement expires.
The signal becomes ”0” when:
· The consumable parts whose service life has expired are re–set on the
periodic maintenance screen.
Format
D Data input
Signal
Periodic maintenance
life expiration output
signal
LIFOVR <F093#0>