B–64113EN–1/01
4. REFERENCE POSITION ESTABLISHMENT
263
Number Message Description
090 REFERENCE RETURN
INCOMPLETE
In case of Linear scale I/F with absolute
address referenced mark (A/B phase),
the actual interval of reference marks is
different from parameter (No.1821,
1882) setting value.
5220 REFERENCE POINT
ADJUSTMENT MODE
In case of Linear scale I/F with absolute
address referenced mark (A/B phase)
or Linear scale with distance–coded
reference marks (serial), the reference
point auto setting parameter
(No.1819#2) is set to ”1”. Move the ma-
chine to reference position by manual
operation and execute manual refer-
ence return.
5325 SERIAL DCL:
FOLLOW–UP ERROR
1. The amount of follow–up is more
than 2147483648 or less than
–2147483649 on detection unit.
To reduce the follow–up amount,
please adjust the point that we be-
gin follow–up.
2. The value of parameter No.1884
is out of range.
5326 SERIAL DCL:REF–POS
ESTABLISH ERR
The amount of movement for establish
reference position was exceeded the
amount of parameter 14010. Please try
again or change parameter 14010 larg-
er.
5327 SERIAL DCL:MISMATCH
(SSYNC CTRL)
Master/slave axes of simple synchro-
nized control, one of them is the linear
scale with distance–coded reference
marks (serial), and the other of them is
not the linear scale with distance–
coded reference marks (serial). Please
establish reference position with the in-
put signal SYNCJn<g140> setting to
zero.
5328 SERIAL DCL:MISMATCH
(ANGL–AXIS)
On angular axis control, one of the an-
gular/perpendicular axes is the scale
with ref–pos, and the other of them is
not the scale with ref–pos. Such system
is not admired.
(*)P/S alarm 5325–5328 is generated only on Linear scale with distance–
coded reference marks (serial)
Alarm and message