B–64113EN–1/01
13. INPUT/OUTPUT OF DATA
945
HCALM When an alarm is issued during hard copy operation:
0 : No alarm message is displayed.
1 : An alarm message is displayed.
HCNEG When a hard copy is taken with the monochrome VGA or character card:
0 : Characters (graphics) are in black, and the background is in while in
the hard copy.
1 : Characters (graphics) are in white, and the background is in black in
the hard copy.
HDCPY Screen hard copy operation is:
0 : Disabled.
1 : Enabled.
CAUTION
In addition to the above parameters, it is necessary to set
4 in parameter No. 20 (I/O channel selection).
The hard copy status is output. When the hard copy start signal (HDCPY,
G67#7) is not set to 1, pressing the reset button resets all bits of diagnostic
number 35 to 0.
#7
0035
#6 #5 #4
HCER3
#3
HCER2
#2
HCER1
#1
HCAB3
#0
HCEND
HCEND Normal termination of hard copy operation
HCAB3 Acceptance of hard copy interruption request
HCER1 Hard copy parameter setting error (= P/S5212)
HCER2 Failure to obtain the right to exclusively use the memory card (= P/S5213)
HCER3 Failure to write data to the memory card (= P/S5214)
Diagnostic screen