B–64113EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
446
NOTE
1 If an axis for which a reference position is established and
an axis for which no reference position is established are
simultaneously specified with G28 when bit 2 (ALZ) of
parameter No. 7055 is set to 1, G28 is executed after turning
off the AI advanced preview control or AI contour control
mode, regardless of the setting of bit 3 (AZR) of parameter
No. 7054.
2 If the serial spindle is switched to the Cs contour control
mode then G00 is specified for the Cs contour control axis
without performing a reference position return operation
even once during AI advanced preview control or AI contour
control when bit 1 (NRF) of parameter No. 3700 is set to 0,
a P/S alarm (No. 090) is issued, regardless of the setting of
bit 2 (ALZ) of parameter No. 7055.
ADP Single direction positioning in the AI advanced preview control or AI
contour control mode is executed:
0 : In the normal mode.
1 : In the AI advanced preview control or AI contour contro mode.
3241 Character blinking in the AI advanced preview control or AI contour control mode
(first character)
to
3247 Character blinking in the AI advanced preview control or AI contour control mode
(seventh character)
[Data type] Byte
[Valid data range] 0 to 225
Set the character codes of characters blinking in the AI advanced preview
control or AI contour control mode.
Set character codes according to the character code list in Appendix A.
NOTE
When 0 is set, “AICC” (AI contour control option is used) or
“AI APC” (AI contour control option is not used) blinks.