B–64113EN–1/01
12. DISPLAY/SET/EDIT
865
Menu
item
Brief description
Parameter
No.
Group
SETTING
1401#6 Whether to enable dry run for rapid
traverse
0: To disable
1: To enable
1410 Dry run speed
1420 Rapid traverse rate for individual axes
1421 Rapid traverse override FO speed for
individual axes
1422 Maximum cutting feedrate (common to
all axes)
1423 Jog feedrate for individual axes
1424 Manual rapid traverse feedrate for in-
dividual axes
1425 FL speed at reference position return
for individual axes
ERATION/
DECEL-
ERATION
1610#0 The cutting feed acceleration/decel-
eration used is:
0: Exponential type acceleration/de-
celeration
1: Post–interpolation linear–type ac-
celeration/deceleration
1620 Rapid–traverse linear–type accelera-
tion/deceleration time constant for in-
dividual axes
1622 Cutting feed acceleration/deceleration
time constant for individual axes
1624 Jog feed acceleration/deceleration
time constant for individual axes
1625 Jog feed exponential acceleration/de-
celeration FL speed for individual
axes
3017 Reset signal output time
3030 Allowable number of M code digits
3701#1 Whether to use spindle serial interface
for all axes
0: To use
1: Not to use
7110 Number of manual pulse generators in