4. REFERENCE POSITION ESTABLISHMENT
B–64113EN–1/01
260
(2)Establish a reference point by the procedure described in ”1.2.1
Procedure for Reference Position Establishment”. (As a result, the
machine coordinate becomes the distance between scale zero and
actual position.)
(3)Positioning the axis to reference position by mechanical measurement
in ”HND” or ”JOG” mode.
(4)Set an actual machine coordinate value (DGN.301) to the parameter
No.1883 after conversion of least command increment to detection
unit. (Multiply DGN.301 and CMR)
(5)Set a parameter No.1240 if necessary.
NOTE
When the setting value is greater than 99,999,999, this
method can’t be used.
[The setting method of parameter No.1883]
(Linear scale with distance–coded reference marks (serial))
You can determine the setting value by the following procedure.
(1)Set ”1” to parameter No.1815#2 to make this function available.
Set ”0” to parameter No.1240.
Set ”0” to parameter No.1883,1884.
(2)Establish a reference point by the procedure described in ”1.3.1
Procedure for Reference Position Establishment”. (As a result, the
machine coordinate becomes the distance between scale zero and
actual position.)
(3)Positioning the axis to reference position by mechanical measurement
in ”HND” or ”JOG” mode.
(4)Set an actual machine coordinate value (DGN.301) to the parameter
No.1883 after conversion of least command increment to detection
unit. (Multiply DGN.301 and CMR)
(5)Set a parameter No.1240 if necessary.
NOTE
When the setting value is greater than 99,999,999, this
method can not be used.
#7
1817
#6 #5 #4
SCPx
#3 #2 #1 #0
[Data type] Bit axis
SCPx If DC2x (Paramete No.1802#2) is set to ’1’, the scale–zero point of the
linear scale with absolute addressing referenced mark is:
0 : On the negative direction side. (Viewed from the scale zero point, the
reference position is on the positive direction side.)
1 : On the positive direction side. (Viewed from the scale zero point, the
reference position is on the negative direction side.)