B–64113EN–1/01
1. AXIS CONTROL
25
#7
6901
#6 #5 #4 #3
PSF
#2
PCM
#1
EPS
#0
IGP
[Data type] Bit
IGP During follow–up for the absolute position detector, position switch
signals are:
0 : Output
1 : Not output
EPS The number of position switches is:
0 : Up to 10.
1 : Up to 16.
PCM Position switch signals are output:
0 : Without considering acceleration/deceleration and servo delay.
1 : With considering acceleration/deceleration and servo delay.
PSF In AI contour control, AI advanced preview control or advanced preview
control mode, position switches are:
0 : Not used.
1 : Used.
To use the position switches in any of the following modes, set this
parameter:
AI contour control, AI advanced preview control mode or advanced
preview control mode
NOTE
The position switch signals are output considering
acceleration/deceleration after interpolation and servo
delay. Acceleration/deceleration after interpolation and
servo delay are considered even for position switch signal
output in a mode other than the AI contour control, AI
advanced preview control, and advanced preview control
modes. When this parameter is set to 1, however, signals
are output from the position switches at different times from
the specified ones.
Parameter
D Increasing the number of
position switch signals