B–64113EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
417
1777
Minimum speed for the automatic corner deceleration function (for advanced
preview control, AI advanced preview control, or AI contour control)
[Data type] Word
Valid data range
y
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Set a speed at which the number of buffered pulses in deceleration is as-
sumed to be 0 when linear acceleration/deceleration before interpolation
is used.
1779
Critical angle subtended by two blocks for automatic corner deceleration (for
advanced preview control, AI advanced preview control, or AI contour control)
[Data type] 2–word
[Unit of data] 0.001 deg
[Valid data range] 0 to 180000
Set a critical angle to be subtended by two blocks for corner deceleration
when the angle–based automatic corner deceleration function is used.
The angle subtended by two blocks is defined as q in the examples shown
below.
Block A (G01)
θ
θ
Angle subtended by two straight lines
Block A (G02)
Block B (G01)
Block B (G01)
Angle subtended by an arc and its tangent
1780
Allowable speed difference for the speed difference–based corner deceleration
function (for linear acceleration/deceleration before interpolation)
[Data type] Word
Valid data range
y
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Set the speed difference for the speed difference–based automatic corner
deceleration function when linear acceleration/deceleration before
interpolation is used.
[Unit of data]
[Valid data range]
[Unit of data]
[Valid data range]