B–64113EN–1/01
A. INTERFACE BETWEEN CNC AND PMC
1124
The figure below illustrates the addresses of interface signals between the
CNC and PMC.
G000 ∼CNC PMC MT
F000 ∼
X000 ∼
Y000 ∼
Following shows table of addresses:
In an item where both T series and M series are described, some signals
are covered with shade ( ) in the signal address figure as shown
below. This means either T series or M series does not have this signal.
Upper part is for T series and lower part is for M series.
[Example 1]
Signals EXLM and ST are common signals, STLK is for T series only
and RLSOT and RVS are for M series only.
STLKRLSOT
#0
RVS
#7
G007
#6
SA
#2
ST
#1
T series
M series
When the PMC–SA1 is used, transmittable signals are restricted as shown
below.
Signal address Description
G000 to G255 Signals transmitted from the PMC to the CNC when
the PMC–SA1 is used
F000 to F255 Signals transmitted from the CNC to the PMC when
the PMC–SA1 is used
As seen from the above table, signals at G256 and higher and those at
F256 cannot be used in a system having the PMC–SA1. Therefore,
features requiring these signals cannot be used.
When the PMC–SB7 is used, transmittable signals are restricted as shown
below.
Signal address Description
G000 to G512 Signals transmitted from the PMC to the CNC when
the PMC–SB7 is used
F000 to F512 Signals transmitted from the CNC to the PMC when
the PMC–SB7 is used
A.1
LIST OF ADDRESSES
A.1.1
Series 0i/0i Mate
Address List
Notes when using the
PMC–SA1
Notes when using the
PMC–SB7