8.MULTI-PATH CONTROL B-63943EN-1/02
- 980 -
Signal
Path selection signals (tool post selection signals)
HEAD<G063.0>,HEAD2,<G062.7>HEAD3,4<G408.1,2>
[Classification] Input signal
[Function] Used to specify the path used with the MDI panel.
[Operation] Operations from the MDI panel are performed on the path specified
with a combination of HEAD, HEAD2, HEAD3, and HEAD4. Path
selection signal combinations and their corresponding paths are as
given below.
Path selection signal
HEAD4 HEAD3 HEAD2 HEAD
G408.2 G408.1 G062.7 G063.0
Selected path
0 0 0 0 Path 1
0 0 0 1 Path 2
0 0 1 0 Path 3
0 0 1 1 Path 4
0 1 0 0 Path 5
0 1 0 1 Path 6
0 1 1 0 Path 7
0 1 1 1 Path 8
1 0 0 0 Path 9
1 0 0 1 Path 10
Loader control selection signal LCBS<G251.1>
[Classification] Input signal
[Function] Used to specify whether to use the MDI with a loader path.
[Operation] When this signal becomes "1", operations from the MDI panel are
performed on the loader path. If there are multiple loader paths,
operations are performed on the loader path with the smallest path
number.
When this signal is "0", pressing and holding down the MDI key
"SHIFT" and the pressing "HELP" allows you to switch between
loader and normal paths.
NOTE
This signal is effective when LSL, bit 0 of parameter
No. 8104, is "1".
When the parameter bit LSL is "0", you cannot
select a loader path with this signal and the MDI
key "SHIFT" + "HELP" operation.