1.AXIS CONTROL B-63943EN-1/02
- 200 -
# 5 SCA In feed axis synchronous control:
0: Synchronous operation is performed when the feed axis
synchronous control manual feed selection signal SYNCJ or the
feed axis synchronous control selection signal SYNC for slave
axes is set to 1.
1: Synchronous operation is performed at all times.
Set this parameter with a slave axis.
# 6 SMS The synchronization error smooth suppress function is:
0: Disabled.
1: Enabled.
Set this parameter with a slave axis.
# 7 SYE When external machine coordinate system shift is specified by
external data input/output for the master axis in synchronous control,
the slave axis is:
0: Not shifted.
1: Shifted by the same amount as specified for the master axis.
Set this parameter with a slave axis.
This function is disabled during normal operation.
#7 #6 #5 #4 #3 #2 #1 #0
8305 SRF SSE SSO
[Input type] Parameter input
[Data type] Bit path
# 0 SSO The uni-directional synchronization function in feed axis synchronous
control is:
0: Disabled.
1: Enabled.
# 1 SSE After emergency stop, the uni-directional synchronization function in
feed axis synchronous control is:
0: Disabled.
1: Enabled.
# 2 SRF In feed axis synchronous control, G28, G30, and G53:
0: Make the same movement along the slave axis as a movement
along the master axis.
1: Make movements along the slave axis and master axis
independently to specified positions.