B-63943EN-1/02 1.AXIS CONTROL
- 23 -
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn124 DTCH8 DTCH7 DTCH6 DTCH5 DTCH4 DTCH3 DTCH2 DTCH1
#7 #6 #5 #4 #3 #2 #1 #0
Fn110
MDTCH8 MDTCH7 MDTCH6 MDTCH5 MDTCH4 MDTCH3 MDTCH2 MDTCH1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
0012 RMVx
[Input type] Setting input
[Data type] Bit axis
# 7 RMVx Releasing the assignment of the control axis for each axis
0: Not released
1: Released
(Equivalent to the control axis detachment signals DTCH1, DTCH2,
and so forth)
NOTE
RMVx is valid when bit 7 (RMBx) of parameter No.
1005 is set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
1005 RMBx MCCx
[Input type] Parameter input
[Data type] Bit axis
# 6 MCCx If a multi-axis amplifier is used, and another axis of the same
amplifier is placed in the control axis detach state, the MCC signal of
the servo amplifier is:
0: Turned off.
1: Not turned off.
NOTE
1 This parameter can be set for a control axis.
2 If the servo motor of an axis subject to control axis
detachment is connected to a multi-axis amplifier
such as 2-axis amplifier, and one axis is placed in
the control axis detach state, servo alarm No. 401
(V ready off) is issued on another axis. This alarm
can be prevented by setting this parameter.
# 7 RMBx The control axis detachment signal for each axis and the setting input
RMV (bit 7 of parameter No. 0012) are:
0: Invalid
1: Valid