B-63943EN-1/02 12.TOOL FUNCTIONS
- 1619 -
The details of the data displayed on the total life data screen are as
follows:
- Sort No.
Item Description
Data length 2byte
Valid data range 1 to maximum number of tools (64, 240, or 1,000)
The number representing a tool of a different type is displayed. The
maximum number of tools differs with the options used.
- Tool type number (T code)
Item Description
Data length 4byte
Valid data range 1 to 99,999,999
The tool type number (T code) set on the tool management data screen
is displayed.
- Total remaining life
Item Description
Data length 4byte
Unit of data When the number of use times is specified: Times
Time specifications: Seconds/milliseconds
Valid data range When the number of use times is specified: 0
to2,147,483,647 times
When time is specified: 0 to 359,999,999 s (99999
hours 59 minutes 59 seconds)
0 to 359,999,999 milliseconds (99 hours 59
minutes 59 seconds 999 milliseconds)
The remaining lives of tools with the same tool type number, as
determined by subtracting the life counter value from the maximum
life, are totaled for each number of times or for each time and
displayed.
- Total life counter
Item Description
Data length 4byte
Unit of data When the number of use times is specified: Time
When time is specified: Seconds/milliseconds
Valid data range When the number of use times is specified: 0 to
2,147,483,647 times
When time is specified: 0 to 359,999,999 s (99999
hours 59 minutes 59 seconds)
0 to 359,999,999 milliseconds (99 hours 59
minutes 59 seconds 999 milliseconds)
The life counter values of the same-type tools set on the tool
management data screen (for each tool type number) are totaled for