3.MANUAL OPERATION B-63943EN-1/02
- 416 -
Jog feed mode or incremental
feed mode
+J1
RT
1st axis move
Rapid traverse rate
Feedrate selected by manual feedrate override signal
WARNING
After the power is turned on, the stroke limit
function does not work until the reference position
return is completed. During this period, the control
unit ignores the RT signal, if it is set to "1", and
keeps moving the tool at a feedrate selected by the
manual feedrate override signal. The parameter
RPD (No. 1401#0) can be set so the rapid traverse
is validated before the reference position return is
completed.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn010 *JV7 *JV6 *JV5 *JV4 *JV3 *JV2 *JV1 *JV0
Gn011 *JV15 *JV14 *JV13 *JV12 *JV11 *JV10 *JV9 *JV8
Gn019 RT
Gn100 +J8 +J7 +J6 +J5 +J4 +J3 +J2 +J1
Gn102 -J8 -J7 -J6 -J5 -J4 -J3 -J2 -J1
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1002 JAX
[Input type] Parameter input
[Data type] Bit path
# 0 JAX Number of axes controlled simultaneously in manual continuous feed,
manual rapid traverse and manual reference position return
0: 1 axis
1: 3 axes