B-63943EN-1/02-01
Edit
Apprv.
Design
Sheet
Title
Draw
No.
107/126
Date
Design
Descri
tion
Date
FANUC Se
ies 30i/31i/32i-
, 31i-
5
PMC Axis Control
2004.10.7
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Set the F0 rate of the rapid traverse override for each axis.
#7 #6 #5 #4 #3 #2 #1 #0
1803 TQF
[Input type] Parameter input
[Data type] Bit path
# 4 TQF When torque control is performed by the PMC axis control, follow-up operation is:
0: Not performed.
1: Performed.
#7 #6 #5 #4 #3 #2 #1 #0
1805 TRE
[Input type] Parameter input
[Data type] Bit path
# 1 TRE When bit 4 of parameter No. 1803 is set to 0 (not to perform follow-up operation
with a torque control command in PMC axis control), the servo error counter is:
0: Updated.
When the error count exceeds the maximum allowable cumulative travel value
(parameter No. 1885), the alarm (SV0423) is issued.
1: Not updated.
No errors are accumulated, so that the alarm (SV0423) is not issued. When the
maximum allowable feedrate is exceeded, however, the alarm (SV0422) is
issued.
To return to position control when this parameter bit is set to 1, a reference position return
operation needs to be performed.
1826 In-position width for each axis
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit
[Valid data range] 0 to 99999999
The in-position width is set for each axis.
When the deviation of the machine position from the specified position (the absolute value
of the positioning deviation) is smaller than the in-position width, the machine is assumed
to have reached the specified position. (The machine is in the in-position state.)
1827 In-position width in cutting feed for each axis