11.SPINDLE SPEED FUNCTION B-63943EN-1/02
- 1520 -
3666
Number of the pitch error compensation position at extremely negative
position for each slave axis when independent pitch error compensation is
performed under simple spindle synchronous control
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word spindle
[Valid data range] 0 to 1023
Set the compensation position number at the farthest end in the
negative direction.
NOTE
1 This parameter is valid if pitch error compensation
on an axis of Cs contour control on the salve side
during simple synchronous spindle control is
carried out just for the slave axis (bit 1 (EPC) of
parameter No. 3601 is set to 1).
2 When using the both-direction pitch error
compensation function, set a compensation
position number for a movement in the positive
direction.
3 The usable number of pitch error compensation
positions and their range depend on the option
configuration.