B-63943EN-1/02 8.MULTI-PATH CONTROL
- 913 -
*1: By setting parameter NMR (No. 8161#0) to 1, you can prohibit
the composite control axis from release from the synchronous or
composite control state even if the axis enters the servo off state.
By setting parameter NSR (No. 8161#7) to 1, you can prohibit
the synchronous control axis from release from the synchronous
or composite control even if the axis enters the servo off state.
- Axis state output signals in synchronous or composite control
State output signal In synchronous control In composite control
Axis moving signals
MVn Fn102
- During movement along the
master or slave axis, the
master axis signal goes "1".
- The slave axis signal is always
"0" (1).
- On the axis on which a move
command is executed, the
signal goes "1". The signal on
the axis along which the tool is
actually moving does not turn
to "1" (1).
Axis moving direction signals
MVDn Fn106
- On the master axis, the moving
direction of the master axis.
- On the slave axis, moving
direction after mirror image
processing.
- Actual moving direction on the
axis (moving direction after
mirror image processing in
composite control).
In-position signals
INPn Fn104
- The master axis signal goes
"1" when both the master and
slave axes are in the
in-position state.
- The slave axis signal is always
"1".
- The signal in the specified path
reflects the state of the moving
axis with that specification.
Reference position
establishment signal
ZRFn Fn120
- The signal on the axis for
which the reference position
has been established turns to
"1".
- The signal on the axis for which
the reference position has been
established turns to "1".
Reference position return
completion signal
ZPn Fn094
- After completion of reference
position return of the master
axis, the signal on the master
axis turns to "1".
- The slave axis is synchronized
with movement of the master
axis, but is not subjected to
reference position return. The
signal turns to "0".
- When the master axis is
parking, the slave axis is
subjected to reference position
return. The signal on the
slave axis turns to “1”.
- The signal on the axis along
which the tool is actually
moving turns to "1".
(1) In a positional deviation check, regardless of the states of these
signals, parameter No. 1828 is used if move command pulses are
sent to the motor (regardless of whether the axis is the master or
slave) as the limit, and parameter No. 1829 if none are sent.