6.INTERPOLATION FUNCTION B-63943EN-1/02
- 680 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1006 ROSx ROTx
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
ROTx, ROSx Setting linear or rotation axis.
ROSx ROTx Meaning
0 0
Linear axis
(1) Inch/metric conversion is done.
(2) All coordinate values are linear axis type. (Is not rounded in 0 to 360
°)
(3) Stored pitch error compensation is linear axis type (Refer to parameter No.3624)
0 1
Rotation axis (A type)
(1) Inch/metric conversion is not done.
(2) Machine coordinate values are rounded in 0 to 360
°. Absolute coordinate values are rounded or not
rounded by parameter No.1008#0(ROAx) and #2(RRLx).
(3) Stored pitch error compensation is the rotation type. (Refer to parameter No.3624)
(4) Automatic reference position return (G28, G30) is done in the reference position return direction and the
move amount does not exceed one rotation.
1 1
Rotation axis (B type)
(1) Inch/metric conversion, absolute coordinate values and relative coordinate values are not done.
(2) Machine coordinate values, absolute coordinate values and relative coordinate values are linear axis
type. (Is not rounded in 0 to 360
°).
(3) Stored pitch error compensation is linear axis type (Refer to parameter No.3624)
(4) Cannot be used with the rotation axis roll over function and the index table indexing function (M series)
Except for the above. Setting is invalid (unused)
NOTE
Just a rotation axis can be subjected to normal
direction control.
5480 Number of the axis for controlling the normal direction
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 1 to the maximum controlled axis number
This parameter sets the controlled axis number of the axis for
controlling the normal direction.
5481 Feedrate of rotation of the normal direction controlled axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] deg/min
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
This parameter sets the feedrate of the movement along the normal
direction controlled axis that is inserted at the start point of a block
during normal direction control.