B-63943EN-1/02 13.PROGRAM COMMAND
- 1689 -
#7 #6 #5 #4 #3 #2 #1 #0
G23 CLR FPM G91 G01
3402
G23 CLR G70 G91 G19 G18 G01
[Input type] Parameter input
[Data type] Bit path
# 0 G01 G01 Mode entered when the power is turned on or when the control is
cleared
0: G00 mode (positioning)
1: G01 mode (linear interpolation)
# 1 G18 Plane selected when power is turned on or when the control is cleared
0: G17 mode (plane XY)
1: G18 mode (plane ZX)
# 2 G19 Plane selected when power is turned on or when the control is cleared
0: The setting of bit 1 (G18) of parameter No. 3402 is followed.
1: G19 mode (plane YZ)
When this bit is set to 1, set bit 1 (G18) of parameter No. 3402 to 0.
# 3 G91 When the power is turned on or when the control is cleared
0: G90 mode (absolute command)
1: G91 mode (incremental command)
# 4 FPM At power-on time or in the cleared state:
0: G99 or G95 mode (feed per revolution) is set.
1: G98 or G94 mode (feed per minute) is set.
# 5 G70 The commands for inch input and metric input are:
0: G20 (inch input) and G21 (metric input).
1: G70 (inch input) and G71 (metric input).
# 6 CLR Reset button on the MDI panel, external reset signal, reset and rewind
signal, and emergency stop signal
0: Cause reset state.
1: Cause clear state.
For the reset and clear states, refer to Appendix in the User's Manual.
# 7 G23 When the power is turned on
0: G22 mode (stored stroke check on)
1: G23 mode (stored stroke check off)
Alarm and message
Number Message Description
PS0010 IMPROPER G-CODE An unusable G code is specified.