17.PMC CONTROL FUNCTION B-63943EN-1/02
- 1998 -
NOTE
RABx is valid only when ROAx is 1.
#7 #6 #5 #4 #3 #2 #1 #0
1201 ZPR
[Input type] Parameter input
[Data type] Bit path
# 0 ZPR Automatic setting of a coordinate system when the manual reference
position return is performed
0: Not set automatically
1: Set automatically
NOTE
ZPR is valid while a workpiece coordinate system
function is not provided. If a workpiece coordinate
system function is provided, making a manual
reference position return always causes the
workpiece coordinate system to be established on
the basis of the workpiece zero point offset
(parameters No. 1220 to No. 1226), irrespective of
this parameter setting.
1241
Coordinate value of the second reference position in the machine coordinate
system
1242
Coordinate value of the third reference position in the machine coordinate
system
1243
Coordinate value of the fourth reference position in the machine coordinate
system
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Set the coordinate values of the second to fourth reference positions in
the machine coordinate system.