B-63943EN-1/02 1.AXIS CONTROL
- 123 -
M1/M2: First/second separate detector interface unit
1
2
3
4
5
6
7
8
Slave
No.
1X
2Y
3Z
4
5B
6C
Controlled
axis
number
Program
axis name
(No. 1020)
CNC
Two-axis
amplifier
Single-axis
amplifier
M1
Two-axis
amplifier
Single-axis
am
lifier
M2
- Manual setting 1
The manual setting 1 is valid when the following parameter have the
following values:
FMD (No. 1902#0) = 1
AES (No. 1902#1) = 0
By manual setting 1, the value set for parameter No. 1023 when the
power is switched on is regarded as a slave number. Specifically, an
axis for which parameter No. 1023 is set to 1 is connected to the
amplifier nearest to the CNC, while an axis for which parameter No.
1023 is set to 2 is the second one from the CNC.
X
Y
Z
B
C
Two-axis
amplifier
Single-axis
amplifier
Single-axis
amplifier
Two-axis
am
lifier
1X1
2Y3
3Z4
4
2
5B5
6C6
Servo axis
number
(No. 1023)
CNC
Controlled
axis
number
Program
axis name
(No. 1020)
By manual setting 1, some of the following functions and values
cannot be used, as described below. They should be used with
automatic setting or manual setting 2.
• No separate detector interface unit can be used; hence, no
separate position detectors can be used.