11.SPINDLE SPEED FUNCTION B-63943EN-1/02
- 1218 -
- Indication of serial spindle load meter and speed meter
410 Spindle load meter indication (%)
411 Spindle motor speed indication (min
-1
)
[Data type] Word spindle
For correct indication of the load meter and motor speed, the
following parameters must be set properly:
Maximum motor speed: Set for each axis in parameter Nos. 4020
(MAIN) and 4196 (SUB).
Load meter indication at maximum output: Set for each axis in
parameter Nos. 4127 (MAIN) and 4276 (SUB).
NOTE
Parameters for (MAIN) and (SUB) must be set when
the spindle switching function is used.
When the spindle switching function is not used, set
the parameters for (MAIN).
445 Position data of position coder (pulse)
[Data type] Word spindle
NOTE
Once spindle orientation is performed after
power-on, position data can be read. To read
position data, set bit 1 of parameter No. 3117 to 1.
(Except when maintenance is performed, bit 1 of
parameter No. 3117 must be set to 0.)
710 Spindle warning No.
[Data type] Byte spindle
The warning number transferred from the spindle amplifier is
indicated.
712 Spindle status error No.
[Data type] Byte spindle
The status error number transferred from the spindle amplifier is
indicated.
When the spindle is disabled by an error such as a PMC signal input
error (for example, when two operation modes are specified at the
same time), a status error is recognized while the spindle is disabled.
When the signal is input normally, the normal operation is resumed.
For details of spindle error numbers, see the description of alarms (SP
alarms) related to serial spindles in the alarm list.