16.MEASUREMENT B-63943EN-1/02
- 1884 -
#7 #6 #5 #4 #3 #2 #1 #0
5005 QNI
[Input type] Parameter input
[Data type] Bit path
# 5 QNI With the tool length measurement function, a tool compensation
number is selected by:
0: Operation through the MDI panel by the operator (selection
based on cursor operation).
1: Signal input from the PMG.
#7 #6 #5 #4 #3 #2 #1 #0
5009 GSC
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 0 GSC When the function for direct input of offset value measured B is used,
an offset write input signal is input from:
0: Machine side
1: PMC side
When the interlock function for each axis direction is enabled (when
bit 3 (DIT) of parameter No. 3003 is set to 0), switching can also be
made between input from the machine side and input from PMC side
for the interlock function for each axis direction.